Leave Your Message

Intelligent wireless automatic gas fire extinguishing device-Perfluorohexanone Series

Automatic gas fire extinguishing devices monitor signals related to electrical fire hazards—such as wire temperature, ambient space temperature, and smoke—through internal fire detection sensors. They enable online measurement, collection, analysis, and control of data. Equipped with RS485 and MODBUS communication interfaces, they can connect to computer monitoring systems. Optional 4G or Lora wireless communication interfaces are available to upload data wirelessly to the cloud platform, allowing users to view on-site data and perform remote control via computer or mobile app from any location.

    Type Designation

    YF-1

    Product Name: Intelligent wireless automatic gas fire extinguishing device
    Product Model: MR/YF□Q-KEG1
    Fire suppressant: Perfluorohexanone
    Product Type: Stand-alone Type
    Trigger Mode: Electric Start + Thermal Start
    Installation Method: Nut Press Fit

     product Display

    YF0
    YF1

    Product features

    It consists of a wireless alarm control unit and a perfluorohexanone fire extinguishing device.
    Simultaneous online detection of wire temperature, ambient temperature, and smoke to prevent electrical fire hazards.
    Equipped with various communication interfaces such as RS485, 4G, and Lora.
    Functions include real-time data collection, historical curves, event recording, and trend analysis.
    The split-type product design allows for easy replacement of the extinguishing unit by the user after deployment, enabling multiple reuses and reducing operational costs.

    Technical Parameters

    Function configuration MR/YF0.18Q/KEG1 MR/YF0.3Q/KEG1 MR/YF0.5Q/KEG1 MR/YF1.0Q/KEG1 MR/YF1.5Q/KEG1
    Agent Quantity 180g 300g 500g 1000g 1500g
    Protected Space ≤0.3m³ ≤0.6m³ ≤1m³ ≤2m³ ≤3m³
    Dimensions 145*80*20mm 145*125*20mm 63*63*362mm 63*63*362mm 63*63*442mm
    Energy Storage Method Non-stored Pressure Type
    Application Method Total Flooding or Local Flooding
    Discharge Time ≤14s
    Discharge Delay Time ≤0.5s
    Nozzle Thermal Clearance Temperature at 400mm from nozzle ≤75
    Surface Temperature of Enclosure ≤75
    Extinguishing Density 100g/m³~130g/m³
    Agent Service Life 6 Years
    Protected Area Requirements Protected area should be relatively enclosed
    Installation Method screw fixation
    Operating Environment -40~+85  95%RH
    Activation Method Logical activation (temperature exceeds 100 and smoke detected simultaneously)
    Remote activation (via host or cloud platform)
    Manual forced start (emergency button, press and hold for 3 seconds)
    Over-temperature activation (when any point of thermal detection line exceeds 170)

    Performance Analysis Table of Different Agents

    Product Comparison Non-pressurized Perfluorohexanone Device Ultra-fine Dry Powder Hot Aerosol HFC-227ea
    Extinguishing Concentration 4%-6% 120g/m3 100g/m3 6.7%-8.7%
    Harmful Concentration 10% Strong Asphyxiation Strong Asphyxiation 9%
    Extinguishing Mechanism Heat absorption & Chemical inhibition Smothering & Oxygen reduction Isolation, smothering & Heat absorption Chemical inhibition
    Pressurized? No No No Yes
    Safe for Occupied Spaces? Yes No No No
    Suitable for Electrical Equipment Yes No Yes Yes
    Residue None Heavy powder residue Some powder,corrosive None
    Safety Risks None Agent can settle High heat released during reaction Pressure leakage risk
    Environmentally Friendly Yes No No No