Product Launch: VSY1-12 Indoor High-Voltage Vacuum Circuit Breaker

Product Launch: VSY1-12 Indoor High-Voltage Vacuum Circuit Breaker

2025-12-23
The VSY1-12 Indoor High-Voltage Vacuum Circuit Breaker represents the advanced design of a new generation of medium-voltage switchgear. Designed for 12kV distribution systems, it covers a rated current range from 630A to 2000A with a rated short-circuit breaking current of up to 31.5kA. The pro...
view detail
Product Launch: SJKCPS Series Control and Protective Switching Device (CPS)

Product Launch: SJKCPS Series Control and Protective Switching Device (CPS)

2025-12-16
The Control and Protective Switching Device (CPS) innovatively integrates motor control and circuit protection functions into a single compact unit. The SJKCPS series is designed for AC380-400V/50-60Hz systems, offering an adjustable overload protection range from 0.4A to 125A, perfectly matchi...
view detail
Weekly Electrical Byte: Demystifying Three-Zone Overcurrent Protection

Weekly Electrical Byte: Demystifying Three-Zone Overcurrent Protection

2025-12-12
Overcurrent protection is a fundamental scheme in power systems. Three-zone overcurrent protection is a sophisticated coordinated scheme comprising Instantaneous Overcurrent Protection (Zone 1), Time-Delayed Overcurrent Protection (Zone 2), and Definite-Time Overcurrent Protection (Zo...
view detail
The Cornerstone of Selective Protection: Why MCBs Don't Have a Rated Icw?

The Cornerstone of Selective Protection: Why MCBs Don't Have a Rated Icw?

2025-12-10
The Miniature Circuit Breaker (MCB) is the system's "last line of defense." Its mission is to act immediately at all costs upon a fault. Therefore, it does not require, nor is it rated for, the "Short-Time Withstand Current (Icw)" parameter, which belongs to the "waiters" (Type B breakers). Dur...
view detail
Product Launch: SC(B)11 Series Resin-Insulated Dry-Type Transformers

Product Launch: SC(B)11 Series Resin-Insulated Dry-Type Transformers

2025-12-09
Our SC(B)11 Series Resin-Insulated Dry-Type Transformers are manufactured with premium materials, advanced technology, and stringent quality control to ensure exceptional reliability and a long service life. Designed for critical applications in high-rises, commercial hubs, airports, tunnels, a...
view detail
2P, 3P, or 4P? The Ultimate Guide to Pole Selection for Transfer Switches

2P, 3P, or 4P? The Ultimate Guide to Pole Selection for Transfer Switches

2025-12-07
In electrical switches, a “Pole” (P) refers to the number of independent circuit paths the switch can control or interrupt. One “pole” corresponds to one independent current-carrying path. For a Transfer Switch, its number of poles determines how many lines it switches s...
view detail
Decoding Icw: The Core Essentials and Selection Guide for Breaker Short-Time Withstand Current

Decoding Icw: The Core Essentials and Selection Guide for Breaker Short-Time Withstand Current

2025-12-04
Short-time withstand current (Icw) refers to the ability of a circuit breaker to withstand a specified short-duration current (e.g., 0.05, 0.1, 0.25, 0.5, or 1 second) under defined voltage, short-circuit current, and power factor conditions without tripping. The rated short-time withstand curr...
view detail
the S13-M: The Future of Hermetically Sealed Transformer Technology

the S13-M: The Future of Hermetically Sealed Transformer Technology

2025-12-02
The S13-M series represents a paradigm shift in transformer design. By adopting a hermetically sealed structure that eliminates the traditional conservator, it completely isolates the internal insulating oil from external oxygen and moisture. The innovative bellows tank wall automatically compe...
view detail
Circuit Breaker Trip Types: The Secret Guardians in Your Switchboard

Circuit Breaker Trip Types: The Secret Guardians in Your Switchboard

2025-11-28
Imagine a tiny metal strip inside your breaker. When you plug in too many devices, excess current flows, just like overworking a muscle. This current heats up the "bimetallic strip." Made of two metals bonded together, they expand at different rates when heated, causing the strip to bend. This ...
view detail
Demystifying the XGN15-12: A Pillar of Modern Power Distribution

Demystifying the XGN15-12: A Pillar of Modern Power Distribution

2025-11-27
The XGN15-12 is a type of high-voltage ring main unit (RMU), a crucial component in 10kV to 12kV electrical distribution networks. Its primary role is to receive and distribute electrical power reliably and safely. The heart of this unit is a Sulfur Hexafluoride (SF6) gas-insulated load switch,...
view detail
HL30-100 Isolating Switch Launched, Delivering Reliable Control for Terminal Power Distribution

HL30-100 Isolating Switch Launched, Delivering Reliable Control for Terminal Power Distribution

2025-11-25
The HL30-100 Isolating Switch is now officially launched. Designed for terminal power distribution circuits with AC 50/60Hz and rated voltage up to 230V/400V, it serves as a main switch for terminal electrical appliances or for controlling motors, low-power appliances, and lighting equipment in...
view detail
Exploring the W1 ACB - An In-Depth Analysis of Its Structure and Working Principle

Exploring the W1 ACB - An In-Depth Analysis of Its Structure and Working Principle

2025-11-20
A Frame Circuit Breaker, also known as an Air Circuit Breaker (ACB), is a core protective component in low-voltage distribution systems, responsible for power distribution and providing protection against overload, short-circuit, and under-voltage faults. The W1 series, as a typical representat...